VoltPro Energy Solar Batteries & Power Electronics
Call: 03190626858
Shopping Cart
โšก Smart Sizing Engine Direct PKR Pricing

Find the Perfect Solar Battery for Your Home

Select your home appliances, enter your required backup hours, and instantly find the best solar batteries for your needs.

100% Verified Battery Sizing Real Appliance Duty Cycles Live Inventory & Stock
โšก
Running Load
0 W (0.00 kW)
โฑ๏ธ
Backup Needed
4 Hours
๐Ÿ”‹
Required Energy
0.00 kWh

1. Select Appliances to Run During Load-Shedding

Apne ghar ke appliances select karein. Quantities aur wattages adjust kar saktay hain.

Quick Presets:

2. How Many Hours of Backup Do You Need?

Select load shedding hours to calculate required battery bank storage.

4 Hours
โ„น๏ธ
Energy Math: At your running load of 0 Watts, operating for 4 hours requires approximately 0.00 kWh (0 Wh) of usable energy. We also include a 15% safety reserve margin so your battery is never drained to zero.

3. Inverter Setup & Battery Preferences

Tell us about your existing setup so we only recommend 100% compatible batteries.

Analyzing your electrical load & matching verified inventory...

Filtering only compatible solar batteries with accurate depth of discharge and voltage.

CALCULATION REPORT

Your Household Backup Assessment

Calculated based on real connected wattage, duty cycle, and inverter efficiency.

Running Load
W
Backup Time
Hours
Usable Energy
kWh
System Voltage
Min Inverter VA
VA
โ„น๏ธ Engineering Assumptions: Includes 90% inverter conversion efficiency and 15% safety reserve margin so battery banks are never drained to damaging cutoff voltages.

Recommended Solar Batteries (Available in Stock)

Showing verified compatible battery configurations directly from our inventory.

๐Ÿ”

Custom Sizing Required for Your Load

We couldn't find a direct online battery match for your exact running load (W) and backup hours (h). This is typical for very high loads or specialized multi-inverter configurations.

Important Solar Battery Sizing Tips

Lithium vs Tubular Depth of Discharge Lithium (LiFePO4) allows 90% usable depth without damage, whereas Lead-Acid/Tubular batteries should only be drained to 50% to prevent rapid plate degradation.
Inverter System Voltage (12V / 24V / 48V) Small loads under 1kW use 12V systems. Medium loads up to 2.5kW use 24V (2 batteries in series). Larger loads over 3kW require 48V banks (4 batteries or 48V lithium) to keep cable currents safe.
Repeatable Daily Backup To maintain daily backup during repeated load-shedding sessions, your solar panels or grid charger must deliver enough power to recharge the bank between outages.